Machine Panel Buttons (MP1)
|
Address |
Description |
|||||||||
|
524 |
MP1 Machine Panel Buttons |
|||||||||
|
Bit |
15 |
14 |
13 |
12 |
11 |
10 |
9 |
8 |
|
|
|
|
mb_JN |
mb_RAPID |
mb_JP |
mb_U |
mb_A |
mb_Z |
mb_Y |
mb_X |
||
|
|
||||||||||
|
|
Bit |
7 |
6 |
5 |
4 |
3 |
2 |
1 |
0 |
|
|
|
mb_ROV100 |
mb_ROV50 |
mb_ROV25 |
mb_ROV0 |
mb_RESET |
mb_STOP |
mb_START |
mb_ESP |
||
Bit15 mb_JN: Negative(-) direction movement command in JOG mode
Bit14 mb_RAPID: RAPID speed selection button
Bit13 mb_JP: Positive(-) direction movement command in JOG mode
Bit12 mb_U: U / (5th) axis selection button
Bit11 mb_A: A / (4th) axis selection button
Bit10 mb_Z: Z axis selection button
Bit9 mb_Y: Y axis selection button
Bit8 mb_X: X axis selection button
Bit7 mb_ROV100: Rapid movement (G00) 100% speed rate selection button
Bit6 mb_ROV50: Rapid movement (G00) 50% speed rate selection button
Bit5 mb_ROV25: Rapid movement (G00) 25% speed rate selection button
Bit4 mb_ROV0: Rapid movement (G00) 0% speed rate selection button
Bit3 mb_RESET: Reset button
Bit2 mb_STOP: Automatic pause button (Normally Closed Contact)
Bit1 mb_START: Start button
Bit0 mb_ESP: Emergency stop button (Normally Closed Contact)
|
|
These definitions are based on the standard MP1 machine panel. On other machine panels, the definitions of these addresses may differ. |
|
Address |
Description |
|||||||||
|
525 |
MP1 Machine Panel Buttons |
|||||||||
|
Bit |
15 |
14 |
13 |
12 |
11 |
10 |
9 |
8 |
|
|
|
|
mb_FOV8 |
Mb_FOV4 |
mb_FOV2 |
mb_FOV1 |
mb_MODE8 |
mb_MODE4 |
mb_MODE2 |
mb_MODE1 |
||
|
|
||||||||||
|
|
Bit |
7 |
6 |
5 |
4 |
3 |
2 |
1 |
0 |
|
|
|
mb_FN2 |
mb_FN1 |
mb_HOME |
mb_TOOL |
mb_COOL |
mb_SCCW |
mb_SSTOP |
mb_SCW |
||
Bit15 mb_FOV8: Cutting feed ratio switch bit 3
Bit14 mb_FOV4: Cutting feed ratio switch bit 2
Bit13 mb_FOV2: Cutting feed ratio switch bit 1
Bit12 mb_FOV1: Cutting feed ratio switch bit 0
Bit11 mb_MODE8: Mode selection switch bit 3
Bit10 mb_MODE4: Mode selection switch bit 2
Bit9 mb_MODE2: Mode selection switch bit 1
Bit8 mb_MODE1: Mode selection switch bit 0
|
|
The MP1 machine panel does not have a mode selection switch. However, a port has been provided at the back of the machine panel for connections, which can be connected externally. |
Bit7 mb_FN2: General purpose operation button 2
Bit6 mb_FN1: General purpose operation button 1
Bit5 mb_HOME: Send axes to home position button
Bit4 mb_TOOL: Tool release button
Bit3 mb_COOL: Coolant on button
Bit2 mb_SCCW: Spindle counterclockwise(CCW) rotation button
Bit1 mb_SSTOP: Spindle stop button
Bit0 mb_SCW: Spindle clockwise(CW) rotation button
|
|
These definitions are based on the standard MP1 machine panel. On other machine panels, the definitions of these addresses may differ. |
|
Address |
Description |
|||||||||
|
526 |
MP1 Machine Panel Buttons |
|||||||||
|
Bit |
15 |
14 |
13 |
12 |
11 |
10 |
9 |
8 |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
||||||||||
|
|
Bit |
7 |
6 |
5 |
4 |
3 |
2 |
1 |
0 |
|
|
|
|
|
|
|
mb_SOV8 |
mb_SOV4 |
mb_SOV2 |
mb_SOV1 |
||
Bit15
Bit14
Bit13
Bit12
Bit11
Bit10
Bit9
Bit8
Bit7
Bit6
Bit5
Bit4
Bit3 mb_SOV8: Spindle speed ratio switch bit 3
Bit2 mb_SOV4: Spindle speed ratio switch bit 2
Bit1 mb_SOV2: Spindle speed ratio switch bit 1
Bit0 mb_SOV1: Spindle speed ratio switch bit 0
|
|
The spindle speed ratio switch on the MP1 machine panel can be set to a value between 0 and 7. |
|
|
These definitions are based on the standard MP1 machine panel. On other machine panels, the definitions of these addresses may differ. |