Pulser3 Installation Download PDF

Machine Panel Buttons (MP1)

Address

Description

524

MP1 Machine Panel Buttons

Bit

15

14

13

12

11

10

9

8

 

 

mb_JN

mb_RAPID

mb_JP

mb_U

mb_A

mb_Z

mb_Y

mb_X

 

 

Bit

7

6

5

4

3

2

1

0

 

mb_ROV100

mb_ROV50

mb_ROV25

mb_ROV0

mb_RESET

mb_STOP

mb_START

mb_ESP

 

Bit15    mb_JN:           Negative(-) direction movement command in JOG mode

Bit14    mb_RAPID:    RAPID speed selection button

Bit13    mb_JP:           Positive(-) direction movement command in JOG mode

Bit12    mb_U:             U / (5th) axis selection button

Bit11    mb_A:             A / (4th) axis selection button

Bit10    mb_Z:             Z axis selection button

Bit9      mb_Y:             Y axis selection button

Bit8      mb_X:             X axis selection button

Bit7      mb_ROV100: Rapid movement (G00) 100% speed rate selection button

Bit6      mb_ROV50:    Rapid movement (G00) 50% speed rate selection button

Bit5      mb_ROV25:    Rapid movement (G00) 25% speed rate selection button

Bit4      mb_ROV0:      Rapid movement (G00) 0% speed rate selection button

Bit3      mb_RESET:    Reset button

Bit2      mb_STOP:      Automatic pause button (Normally Closed Contact)

Bit1      mb_START:    Start button

Bit0      mb_ESP:        Emergency stop button (Normally Closed Contact)

These definitions are based on the standard MP1 machine panel. On other machine panels, the definitions of these addresses may differ.

 

Address

Description

525

MP1 Machine Panel Buttons

Bit

15

14

13

12

11

10

9

8

 

 

mb_FOV8

Mb_FOV4

mb_FOV2

mb_FOV1

mb_MODE8

mb_MODE4

mb_MODE2

mb_MODE1

 

 

Bit

7

6

5

4

3

2

1

0

 

mb_FN2

mb_FN1

mb_HOME

mb_TOOL

mb_COOL

mb_SCCW

mb_SSTOP

mb_SCW

 

Bit15    mb_FOV8:      Cutting feed ratio switch bit 3

Bit14    mb_FOV4:      Cutting feed ratio switch bit 2

Bit13    mb_FOV2:      Cutting feed ratio switch bit 1

Bit12    mb_FOV1:      Cutting feed ratio switch bit 0

Bit11    mb_MODE8:   Mode selection switch bit 3

Bit10    mb_MODE4:   Mode selection switch bit 2

Bit9      mb_MODE2:   Mode selection switch bit 1

Bit8      mb_MODE1:   Mode selection switch bit 0

The MP1 machine panel does not have a mode selection switch. However, a port has been provided at the back of the machine panel for connections, which can be connected externally.

 

Bit7      mb_FN2:        General purpose operation button 2

Bit6      mb_FN1:         General purpose operation button 1

Bit5      mb_HOME:     Send axes to home position button

Bit4      mb_TOOL:      Tool release button

Bit3      mb_COOL:     Coolant on button

Bit2      mb_SCCW:     Spindle counterclockwise(CCW) rotation button

Bit1      mb_SSTOP:   Spindle stop button

Bit0      mb_SCW:       Spindle clockwise(CW) rotation button

These definitions are based on the standard MP1 machine panel. On other machine panels, the definitions of these addresses may differ.

 

Address

Description

526

MP1 Machine Panel Buttons

Bit

15

14

13

12

11

10

9

8

 

 

 

 

 

 

 

 

 

 

 

 

Bit

7

6

5

4

3

2

1

0

 

 

 

 

 

mb_SOV8

mb_SOV4

mb_SOV2

mb_SOV1

 

Bit15   

Bit14   

Bit13   

Bit12   

Bit11   

Bit10   

Bit9     

Bit8     

Bit7     

Bit6     

Bit5     

Bit4     

Bit3      mb_SOV8:      Spindle speed ratio switch bit 3

Bit2      mb_SOV4:      Spindle speed ratio switch bit 2

Bit1      mb_SOV2:      Spindle speed ratio switch bit 1

Bit0      mb_SOV1:      Spindle speed ratio switch bit 0

The spindle speed ratio switch on the MP1 machine panel can be set to a value between 0 and 7.

 

These definitions are based on the standard MP1 machine panel. On other machine panels, the definitions of these addresses may differ.