Overview
|
Variable No |
Modbus TCP Address |
Description |
Length |
|
0 |
0 |
General purpose Non-Holding operator variables |
200 |
|
100 |
200 |
General purpose holding operator variables |
200 |
|
|
400 |
Built-In inputs |
4 |
|
|
404 |
External inputs (External module 1) |
4 |
|
|
408 |
External inputs (External module 2) |
4 |
|
|
412 |
External inputs (External module 3) |
4 |
|
|
416 |
External inputs (External module 4) |
4 |
|
|
420 |
External inputs (External module 5) |
4 |
|
|
424 |
External inputs (External module 6) |
4 |
|
|
428 |
External inputs (External module 7) |
4 |
|
|
432 |
External inputs (External module 8) |
4 |
|
|
436 |
External inputs (External module 9) |
4 |
|
|
440 |
External inputs (External module 10) |
4 |
|
|
444 |
Spindle encoder counter |
2 |
|
|
446 |
M.P.G. counter |
2 |
|
|
448 |
Signals Sent from CNC to PLC |
32 |
|
|
480 |
Alarm bits |
32 |
|
|
512 |
Reserved |
12 |
|
|
524 |
Machine panel buttons |
4 |
|
|
528 |
Timers (48x4Word) |
192 |
|
|
720 |
Counters (48x4Word) |
128 |
|
|
848 |
PLC axis statuses |
64 |
|
|
912 |
PLC auxiliary bits (used by PLC software) |
88 |
|
|
1000 |
Built-in outputs |
2 |
|
|
1002 |
Reserved |
1 |
|
|
1003 |
Built-in analog output |
1 |
|
|
1004 |
External outputs (External Module 1) |
4 |
|
|
1008 |
External outputs (External Module 2) |
4 |
|
|
1012 |
External outputs (External Module 3) |
4 |
|
|
1016 |
External outputs (External Module 4) |
4 |
|
|
1020 |
External outputs (External Module 5) |
4 |
|
|
1024 |
External outputs (External Module 6) |
4 |
|
|
1028 |
External outputs (External Module 7) |
4 |
|
|
1032 |
External outputs (External Module 8) |
4 |
|
|
1036 |
External outputs (External Module 9) |
4 |
|
|
1040 |
External outputs (External Module 10) |
4 |
|
|
1048 |
Signals sent from PLC to CNC |
32 |
|
|
1080 |
Reserved |
12 |
|
|
1092 |
Machine panel LEDs |
4 |
|
|
1096 |
Reserved PLC memory area for general purpose use |
704 |
|
|
1100 |
PLC axis commands |
64 |
|
|
1800 |
Reserved holding PLC memory area for general purpose use |
200 |
|
1000 |
2000 |
Reserved for system use |
2000 |
|
2000 |
4000 |
System actual value display area |
2000 |
|
3000 |
6000 |
Reserved for system use |
800 |
|
3400 |
6800 |
Tool length compensation values (100 units) |
100 |
|
3500 |
7000 |
Tool radius compensation values (100 units) |
100 |
|
3600 |
7200 |
Tool length wear compensation values (100 units) |
100 |
|
3700 |
7400 |
Tool radius wear compensation values (100 units) |
100 |
|
3800 |
7600 |
Work offset values (G54~G59.4, G92) |
176 |
|
4000 |
8000 |
General-purpose holding operator variables |
2000 |
|
5000 |
10000 |
Reserved for system use |
2000 |
|
6000 |
12000 |
G code list, library, MDI box, FTP file name |
2000 |
|
7000 |
14000 |
Parameters (500 units) |
1000 |
|
7500 |
15000 |
System parameters (500 units) |
1000 |
|
8000 |
16000 |
Commands directed to subprogram |
200 |
|
8100 |
16200 |
Bits directed to subprogram |
200 |
|
8200 |
16400 |
Reserved for system use |
3600 |